PRISMA 2020 replaced the 2009 statement and redesigned the flow diagram. Most health sciences journals now expect the 2020 version. This is what actually changed and what it means for your records.
Registers are counted separately from databases
The 2009 diagram had a single box for the database search. PRISMA 2020 splits it, and trial registers such as ClinicalTrials.gov or the WHO ICTRP are counted on their own line, not mixed in with MEDLINE and Embase. If your search log does not tell them apart, you will need to go back and separate the counts.
Records removed before screening are broken down
The old diagram folded everything before screening into deduplication. PRISMA 2020 asks for three numbers: duplicate records removed, records marked as ineligible by automation tools, and records removed for other reasons. The automation line was added because screening classifiers became common; zero is a normal answer if you did not use one.
Studies found by other routes get their own column
In 2009, studies found through citation searching or hand-searching were pushed through the same funnel as the database results, which never described what really happened. PRISMA 2020 gives them a parallel column that skips title and abstract screening, because you assess those reports directly.
Each reason for exclusion gets its own count
The 2009 diagram already asked for full-text articles excluded "with reasons". PRISMA 2020 asks for a count for each reason (Reason 1, n = …; Reason 2, n = …) in the box of reports excluded. If you are reconstructing an older review, this is usually the hardest part to recover, which is a good argument for recording reasons as you screen rather than afterwards.
Studies and reports are told apart
PRISMA 2020 is careful about the difference between a study and areport of that study. A trial published in one main paper and two secondary analyses is one study and three reports. The diagram asks for both counts at the included stage.
If your review started on PRISMA 2009
You can usually still produce a 2020 diagram, because the extra fields are mostly splits of numbers you already have. The two that tend to cause work are separating registers from databases and recovering the reasons for exclusion. If a number genuinely cannot be reconstructed, say so in the methods rather than inventing it: reviewers accept a documented gap far more readily than a figure that does not add up.